Public records library › 26-598 › ENGINEERING REVIEW MEMO.pdf
Request 26-598
ENGINEERING REVIEW MEMO.pdf
PDF · 45 KB · released by the City of Moscow on request 26-598
The original PDF opens in a new tab. Open the PDF.
SHA-256 6b71ef88e5507d2d2ab3e78e95f33220e9432ecc1578e352521c76cca5c3852d
Extracted text
Machine-extracted text layer of the file above, shown verbatim for search and reading. Tables and slides lose their layout. The original file governs.
# ENGINEERING REVIEW MEMO.pdf - path: - path: ENGINEERING REVIEW MEMO.pdf - type: pdf - size: 45052 bytes - pages: 2 - extraction method: text layer (pypdf) --- Page 1 --- City of Moscow Engineering Dept. Memo To: Michael Ray, Planning Manager From: Bob Buvel, Senior Civil Engineer cc: Scott Bontrager, City Engineer; Jennifer Fleischman, Administrative Assistant – Capital Projects & Deputy City Clerk. Date: June 17, 2025 Re: Department Review of the Woodbury Addition Re-Plat and Planned Unit Development After reviewing the preliminary re-plat and planned unit development (PUD) for the Woodbury addition, the engineering department has a few of recommendations for consideration at this stage of the re-platting process. We don’t anticipate that the traffic on Mountain View Road will increase significantly from the original plat to the re-plat. Based on the TIS submitted with the original plat, the additional lots won’t have a significant impact on the LOS at F Street and Mt. View. The improvements on Mt. View to mitigate the impact of the Woodbury Subdivision have already been installed. As with the original plat, more analysis/mitigation may be required when the connection to Orchard Ave. is completed. The increase in the number of lots and density from the original plat will have an impact on some of the utility systems . As a result, please consider the following: 1. The addition lots will have a negligible impact on domestic water demand in the area, however the addition of NB zoned lots with potential commercial uses may increase the fire flow demand in the subdivision. The water modeling report for the original plat was done prior to upgrades to the Ponderosa pump station and it recommended connecting to the main pressure zone in Slonaker as the Ponderosa station was insufficient to serve the development. After that water model analysis was completed, the City constructed a new pump station serving the Orchard Ave. pressure zone and the Woodbury Addition was included in the potential service area of that pump station design. The developer has also constructed a connection to that pressure zone and installed a PRV near the connection to the main pressure zone in Slonaker, expanding the Orchard Pressure Zone as intended in the new pump station design. Flow tests of the system near the new commercial lots indicate an available fire flow of 3800 gpm. Fire Flow at that capacity should be sufficient to serve the majority of uses in the NB Zone. Any supply deficiencies for other uses can be mitigated by installing fire suppression systems in the --- Page 2 --- 2 building and/or constructing a building with a more fire-resistant building construction type. 2. Because of the increased density and subsequent increase in overall impervious area of the development, the Woodbury stormwater report will need to be revised and any necessary modifications to the existing detention pond will need to be completed with the next phase of the development. 3. The sanitary system as designed should be suffic ient to serve the additional lots however the additional demand will exacerbate the issue downstream of Slonaker and the planned Lanny connection should be required with the next phase of the development. 4. The proposed re-plat shows the Woodbury Drive RO W width decreasing from Sixty feet (60’) to Fifty-Four feet (54’) north of Cottage Lane. The proposed re-plat indicates that Woodbury will continue to be a public street. The Woodbury ROW shall stay 60’ wide if it is going to be a public street. This concludes our comments for this preliminary application. Please let me know if you have any questions or comments. Regards, Bob Buvel